← Back to Projects

Logic and Power PCB

I modified the SR-01 power and logic boards and brought the servo path up on the V2 logic board.

Robotics & Controls Intern · Sep. 2026 – Present · Working prototype · Serpent Robotics

  • Teensy 4.1
  • PCA9685
  • TCA9548A
  • I2C
  • Logic PCB
  • Power PCB

Key outcomes

  • Diagnosed an active-low output-enable fault on the PCA9685. Driving GPIO 6 low let the servo move.
  • Teensy 4.1, TCA9548A at 0x70, PCA9685 at 0x40. Register writes read back, and the servo frame is set to 50 Hz.
  • Modified the boards as one set: 5–20 A fused paths, modular DC-DC, and RS-485 and I2C.
Logic board on a blue bench mat, with a Teensy 4.1 installed and a DC-DC module at the top
V2 logic board during bring-up. This is the revision I tested. The Teensy 4.1 is installed. This photo is the board, not a meter reading.
50 Hz
Servo PWM
12 V
Metered rail
6 V
Metered rail

Project overview

Green logic PCB with white connectors, labeled for stepper, encoder, and RS-485

Two boards from the SR-01 set. Servo commands on the logic board go from a Teensy 4.1, through a TCA9548A, to a PCA9685, and out as 50 Hz PWM. Output enable is not another I2C hop. It is Teensy GPIO 6 into the PCA9685 OE pin, and OE is active low. RS-485 is still on the same board.

The power board is the fused distribution: terminal blocks, blade fuses, a yellow XT60, and modular DC-DC converters. The fuse and regulator sheets are that board.

System architecture

Teensy 4.1 on the logic board, with SDA and SCL marked beside the green connectors
Teensy 4.1 on the logic board. The silkscreen by the green connectors is marked SDA and SCL. This is the connector, not a bus capture.

I2C from the Teensy through the TCA9548A to the PCA9685. The scan names what answers, and a register write has to read back.

Power board
Fused distribution into the actuators. Blade fuses are installed, including one marked 15. A later photo shows modular DC-DC converters on this board.
Logic board
Teensy 4.1, plus stepper, encoder, RS-485, I2C, and proximity connectors. Power inputs are marked 12 V, 5 V, and ground.
Servo path
TCA9548A multiplexer into a PCA9685. Sixteen channels of 12-bit PWM, set to 50 Hz.

Engineering decisions

DecisionAlternativeWhy
Fuse the actuator pathLeave the actuator supply unprotected and hope the driver limits current.I put 5–20 A fused circuits, DC-DC regulation, and RS-485 and I2C onto the power and logic boards as one set of changes.

Implementation

V2 power board with an XT60, ATAZ converter modules, and terminal blocks

I modified the power and logic boards, checked the rails with a meter, and brought up the Teensy servo path on the logic board. The grip-test cascade is still the earlier failure on record. I don't have a photo of a replacement control board.

The SR-01 logic and power boards, including V1 on the homework sheet and the later V2 pair I tested. I did not draw a new schematic for this page, and I did not design the chassis.

SDA is bidirectional. A one-direction isolator cannot carry it. I looked at bidirectional I2C isolators, including the Si8600, and checked the bus across separate supplies.

Debugging and validation

The grip test took the control board

Problem
During a branch-grip test the printed link broke while grabbing the branch.
Diagnosis
The printed link was in the electrical path.
Fix
There is no replacement-board photo and no bring-up note for a new control board.

Results and future work

Servo path. One channel moved after output enable was driven. The checks, and what is still open, are in the bring-up above. Rails I have checked. 12 V and 6 V, and the actuator interfaces, with a multimeter during bring-up. That is not a stability run. What failed earlier.

The grip test took out the control board and half the actuators. That replacement is still open. It is a different fault from the servo that sat still.

Still open. Fuse markings are not mapped to a branch. CURRENT_S and VOLTAGE_S are on the power schematic and have not been logged.

  • Replace the failed control board and bring the rails back up on the new board.
  • Map the fuse markings to the branches on the power sheet.
  • Run the servo long enough to log current and watch the rail. That test has not started.

Related work

Full engineering log
V2 logic board on a blue mat, with a Teensy 4.1 installed
V2 logic
V2 power board with an XT60, ATAZ converter modules, and terminal blocks
V2 power
Servo on the logic board

A blue servo in hand, wired back to the Teensy board. The connector board is on the mat behind it. I am not reading a pulse width off this clip.

The two boards

One board feeds the robot. The other tells it what to do.

SR-01 climbs a rope and cuts a branch. The actuators need current at more than one voltage. The controller needs a clean conversation with the sensors and with the PWM controller. Those are different electrical jobs, so they are different boards.

The pair on the homework sheet is V1. The boards went through more than one revision after that. The meter checks and the servo bring-up were on V2.

Both boards on the mat
Two green boards on a blue mat, with a meter reading 0.000 and probes on the bench

The connector board and the Teensy board on the blue mat, with a meter and probes. The meter in this frame reads 0.000. That is not a rail check.

Power PCB

Power distribution, regulation, and electrical protection

Takes the pack and hands it out as branches that are not the same voltage and not the same current. Fuses sit on those branches. Converters make the rails the rest of the robot can actually use. Sensing is on this board so the distribution can be watched, not only switched.

Logic PCB

Embedded control, sensor integration, and actuator interfaces

The Teensy coordinates the peripherals. Sensors come in. Commands go out as PWM pulses, bus messages, and enable pins. Motor current still comes from the power board.

In the design

The blocks below are how the two boards are divided. They are the sheets I worked from, not a new schematic.

What I changed

Fused paths in the 5–20 A range, DC-DC, and RS-485 and I2C, as one set of modifications on the boards I had. I did not design the chassis.

What I have shown

On V2: Teensy to the mux at 0x70, channel 7, PCA9685 at 0x40. Register readback, 50 Hz widths stored, GPIO 6 driven low, one servo moved. 12 V and 6 V on a meter.

Still open

CURRENT_S and VOLTAGE_S are not logged. The sensors are not brought up. Fuse markings are not mapped to branches. No emissions number. The grip-test board is not replaced.

Power flow
  1. 24 V pack

    XT60 into the power board

  2. Fused branches

    24 V distribution, and a feed for the regulators

  3. Regulated rails

    Isolated 12 V, 5 V, and V_SERVO

  4. Loads

    Actuators, 12 V sensors, and the logic board

Information flow
  1. Sensors

    IMU, encoders, proximity

  2. Teensy 4.1

    Reads, decides, enables

  3. Buses

    I2C mux, RS-485, stepper link

  4. Commands

    Pulses and messages, not winding current

The top row is energy. The bottom row is information. They meet at an actuator, and they are not the same wire. A valid command with a dead rail sits still. A healthy rail with output enable held off sits still too.

Power PCB

From a 24 V pack to rails the robot can use

The sensing block is the one to open if you only open one. CURRENT_S and VOLTAGE_S are in the design. I have not logged those readings on V2.

Power board
Power board with a yellow XT60 and blade fuses marked 7.5, 5, and 40

This is not the V2 board with the ATAZ modules. Yellow XT60 on the left, a grey part marked 220 and 2603, and four blade fuses: 7.5, one I cannot read, 5, and 40. I have not mapped those fuses to branches, and I am not reading a pack voltage off the connector.

Current and voltage monitoring

Not brought up

Power sensing

What it does
Produces two analog signals, CURRENT_S and VOLTAGE_S. The parts on the sheet are an ACS770 Hall-effect current sensor, an AMC3311 isolated voltage-sense amplifier, a TLV9001 for conditioning, and an LP5907 3.3 V regulator for that circuitry.
Why the robot needs it
Distributing power without watching it means a stall, a sagging pack, or a rail that has already collapsed only shows up as a dead actuator.
The electrical idea
The ACS770 reads current with a Hall element, so the sense path is not a shunt dropped into the high-current conductor. The AMC3311 measures voltage across an isolation barrier, so the sense circuit does not have to share a ground with the pack. The TLV9001 scales that analog level. The LP5907 is a quiet 3.3 V rail for the sensing parts, separate from a noisy switcher output.
Where it sits
These signals are how the power board could tell the rest of the robot what the pack and the loads are doing. They are designed. I have not logged CURRENT_S or VOLTAGE_S, and I have not checked them against a meter.

Logic PCB

Commands, sensors, and the pins that let them out

The servo block is the path I ran on V2. The sensor blocks are interfaces in the design, not measurements I have taken.

The two logic boards
Connector board marked Encoder next to the Teensy logic board

The connector board is on the left. It is marked Encoder, and the long black header is open. The Teensy board is on the right, with a black module at the top.

Scope during that session

Rigol scope from the same session. A repeating trace is on the screen. I am not reading the volts or the time off it.

Header on the connector board

Soldering the header on the connector board. The white connectors are already on it.

Servo control

Checked on V2

Servo.SchDoc

What it does
A PCA9685 makes 16 channels of 12-bit PWM from I2C commands. The Teensy sends a width. The chip repeats the pulse.
Why the robot needs it
Bit-banging sixteen servo frames on the Teensy would spend the controller on timing. A pulse chip holds that timing so the Teensy can keep talking to everything else. The pulses still do nothing until the power board is feeding the servo.
The electrical idea
The chip I reached is at 0x40, behind multiplexer channel 7, framed at about 50 Hz. Output enable is a separate pin, active low, on Teensy GPIO 6. The servo sheet also has an ADuM1201, a digital isolator for signals that are already one direction, and SS54 Schottky diodes in the protection around that circuitry. A Schottky gives a reverse or a flyback current somewhere to go that is not a driver pin. I have not traced which net the ADuM1201 or each diode sits on.
Where it sits
This is the bring-up. The chip stored 0x55 and 0xAA, and it stored pulse widths, and the horn stayed still until firmware drove GPIO 6 low. One servo moved. That is not sixteen servos, and it is not an endurance run.
The chain and the enable pin

Why it is built this way

What the split is buying, and what it is not

Two boards

High current stays on the power board. The Teensy, the sensors, and the buses stay on the logic board. A fault in a motor branch then has a fuse and a rail between it and the controller. I can bring up a bus without the actuator supply on, and I can replace one board without relaying out the other. The cost is a connector between them, and a ground scheme that has to be chosen on purpose. The grip test is the case where that separation was not enough. The control board from that test is still not replaced in a note.

Four-layer planes

These boards are four-layer, so a ground plane and a power plane exist under the signals. Return current can spread in the plane instead of traveling a long trace beside the bus. That is the reason for the stackup. I have not measured the plane impedance, and I am not claiming an emissions number from it.

Switcher noise

Every module on these boards still switches. The loop from the switch node to its input capacitor wants to be short, and it wants to be away from SDA, SCL, and the analog sense lines. Placement is the control I actually have. I have not run an emissions test.

Decoupling and filtering

Bulk capacitors hold a rail up when a load steps. Smaller capacitors next to a chip cover the fast edges the bulk part is too far away to see. The sheets put both around the converters. A capacitor value on a schematic is not a measurement of ripple.

Transients and reverse current

A motor that stalls, or a linkage that breaks, can push current backward. Fuses, the Schottky parts, and the isolated domains are the places that current is supposed to stop. A fuse is slow relative to a spike, and isolation does not clamp winding current. I have not characterized that transient.

Where parts sit

Connectors go to the edge so a harness can leave the board. Test points go on nets I have to probe during bring-up. On the V2 photos, the modules sit off the Teensy. I am not pinning the current sensor or the isolators, because I cannot pick those chips out of the pictures.

On the boards

Only the regions I can see

The first two photos are V2, which is what I tested. The third is V1. Hover or select a box. A box only marks a part I can see.

V2 power board with an XT60, two ATAZ converter modules, a shielded module, blade fuses, and green terminal blocks
V2 power board, the revision I tested. Boxes sit on the XT60, the fuse holders, the two modules whose labels I can read, the shielded converter, and the output terminals.

The yellow XT60, low on the left of the board. That is the pack connector on Battery_Input. I am not reading a pack voltage off it.

Bring-up

A command, a pulse, and a horn that did not move

The robot

SR-01 climbs a rope and cuts a branch so the arborist can stay on the ground. The boards have to feed the actuators, read the sensors, and carry commands between those parts.

The problem

On the logic board, the servo chip accepted commands and the servo did not move. A valid message was not a motion.

The fix

Output enable, on Teensy pin 6, had never been turned on. Driving that pin low let the stored pulses out. The servo moved.

The engineering challenge

When a good command still doesn't move the servo

During logic-board bring-up, the microcontroller was talking to the servo controller. The connected servo did not move. Software that the chip accepted was not, by itself, a hardware response.

Any of these looks the same from the bench. The work was to find which one it was, instead of editing code at random or replacing parts.

  • The motor supply never arrived
  • The bus never connected
  • The switch was on the wrong channel
  • The pulse width was wrong
  • The connector was miswired
  • The servo or the pulse pin was damaged
  • The outputs were switched off in hardware

How a position request gets out

The chain, and the switch that is not on it

Select a block. The short version is open. Addresses and timing stay folded until you want them.

Command path

Output enable, on its own pin

In plain terms

The embedded controller. This is the board that runs my code and decides what an actuator should do.

Addresses, pins, and timing

It talks to the chips on its Wire2 I2C port. GPIO 6 is a separate pin. It is not part of that bus, and a successful bus scan does not set it.

How I narrowed it

Seven checks, in order

Each step retires one way the servo can sit still. I did not skip to the pin that was wrong.

  1. 1

    Could the controller see anyone?

    Hypothesis

    If the bus is dead, or its supply is missing, nothing downstream can answer.

    Test

    Diagnostic C++ on the Teensy scanned its I2C ports. A meter checked the supply the communication parts actually need.

    Result

    That circuitry wanted its own power connection. Once it had it, the scan found the multiplexer at 0x70.

    Why that step mattered

    There is no point setting a pulse width if the controller cannot see the switch that leads to the pulse chip.

  2. 2

    Which door is the pulse chip behind?

    Hypothesis

    The multiplexer has eight channels. The pulse chip is on one of them, or it is not there.

    Test

    The firmware selected each channel in turn and scanned for devices behind it.

    Result

    Channel 7 answered with the PCA9685 at 0x40. The other channels were not where this servo lives.

    Why that step mattered

    A command sent down the wrong channel looks exactly like a chip that is ignoring you.

  3. 3

    Can it answer, or only listen?

    Hypothesis

    A chip that accepts a write might still be handing back garbage. Both directions have to work.

    Test

    I wrote 0x55, read it back, then did the same with 0xAA, through the multiplexer to the pulse chip.

    Result

    Both patterns came back unchanged. The controller can send a command and retrieve what the chip stored.

    Why that step mattered

    This retired the bus, the channel, and a one-way connection. The command was really landing.

    Register check, through the multiplexer
    TCA: PASS
    Channel 7 selection: PASS
    PCA9685: PASS
    
    Written: 0x55 | Read: 0x55 | PASS
    Written: 0xAA | Read: 0xAA | PASS
  4. 4

    Did the chip store a servo pulse?

    Hypothesis

    The conversation can work while the pulse settings are still wrong for a servo.

    Test

    I set the frame to about 50 Hz and wrote a width on all 16 channels, then read those registers back.

    Result

    The registers matched. The chip was holding the instructions. That still does not mean a pin was moving.

    Why that step mattered

    Servo position is the width of a short pulse inside a 20 ms frame. Storing the width is the software half of that.

    Three position requests inside one 20 ms frame

    About 50 of these frames fit in a second. A wider pulse asks for a different position. The drawing shows the first 3 ms, stretched so the widths are easy to compare. The other 17 ms of each frame stays low. These are the widths I configured, not a trace I read off the scope.

    1 ms
    1.5 ms
    2 ms
    How a 12-bit count becomes those widths

    The PCA9685 splits one frame into 4096 counts. Across 20 ms, one count is about 4.9 µs. A 1 ms pulse is about 205 counts, 1.5 ms is about 307, and 2 ms is about 410. That is the register value the width maps to. It is not a measurement of the pin.

  5. 5

    Is the pulse actually on the wire?

    Hypothesis

    The connector, the supply at the servo, the channel I probed, or a damaged output could still hide a good register.

    Test

    A meter checked the connector supply and the wiring. A scope looked for a pulse. I tried more than one output so a single mislabeled channel was not the whole story. I also checked whether a short had killed the path.

    Result

    The digital path was still answering, so the architecture had not been destroyed. The servo still did not move. I am not reading a pulse width off the scope photo.

    Why that step mattered

    This is the handoff from 'the chip remembers it' to 'the wire is doing it.' Those are different facts.

    On the scope
    Oscilloscope, the logic board, and a small servo on the bench during the pulse check

    Scope, logic board, and a servo while I looked for a pulse. This photo is the setup. It is not a measured width.

  6. 6

    The outputs were never unlocked

    Hypothesis

    Something downstream of a correct register was still blocking the pin.

    Test

    I traced output enable on the schematic to Teensy GPIO 6 and checked whether firmware had driven it.

    Result

    It had not. The pulse generator inside the chip was programmed. The output stage in front of the pins was held off.

    Why that step mattered

    A register write and a pin are not the same circuit. OE sits between them.

    Before
    1. Valid I2C command
    2. Pulse width stored
    3. Outputs still disabled
    4. No servo motion
    After
    1. Valid I2C command
    2. Pulse width stored
    3. Outputs enabled
    4. The servo moved
  7. 7

    Drive the enable, then watch the horn

    Hypothesis

    If OE is the only gate left, driving it the way the pin expects will let the stored pulses out.

    Test

    I set GPIO 6 as an output and drove it low, because this enable is active low.

    Result

    The servo moved. One channel, on the bench. Not a life test.

    Why that step mattered

    The change is two lines because the bug was a gate, not a bad pulse calculation. The earlier checks are what made those two lines the right edit.

    The enable, and nothing else
    pinMode(6, OUTPUT);
    digitalWrite(6, LOW);

    The first line makes pin 6 drive the wire. The second turns the outputs on, because OE is active low. Until then, a correct pulse width had a closed gate in front of it.

What held, and what has not been run

One moving servo is not a finished robot

Done on the bench

  • Multiplexed I2C: the switch at 0x70, and the pulse chip at 0x40 on channel 7.
  • A write of 0x55 and a write of 0xAA, each read back through that same path.
  • About 50 Hz on the pulse chip, with widths stored and read back on all 16 channels.
  • Output enable traced to GPIO 6, then driven low.
  • One servo moved after that enable.

Not done

  • Running a servo long enough to call it an endurance test.
  • Current draw, and whether the supply holds under that load.
  • Temperature of the boards and the servo.
  • A measured reverse-current or transient test.
  • The rest of the actuators and sensors on these connectors.

When It Broke

What failed

The grip test took the control board

Problem
During a branch-grip test the printed link broke while grabbing the branch. Stepper current dropped suddenly and fed back. Signals were delayed by about 5 seconds.
Diagnosis
The printed link was in the electrical path. When it broke, the current spike killed the control board and half the actuators, not just the plastic.
Fix
There is no replacement-board photo and no bring-up note for a new control board. Fusing was the change meant to give that fault current a place to stop.
How I checked this

The checks I have done on the boards in hand are meter readings of the 12 V and 6 V rails and the actuator interfaces, including when a channel stays down. I don't have a measurement from the moment the link broke.

A stalled motor, a broken mechanical stop, and a driver that never limits current can all end at a dead control board. The link breaking is what this test recorded. I am not treating the brushed-to-BLDC saw change as finished. That change was started because the brushless saw draws less current and the old one often got stuck.

Bring the rails back up on a replacement control board. Map the fuse markings to the branches on the power sheet. Finish the saw motor change only with a current measurement.

Results & Validation

What held up

What worked in the end, what I can show for it, and where it's still limited.

Servo path

One channel moved after output enable was driven. The checks, and what is still open, are in the bring-up above.

Rails I have checked

12 V and 6 V, and the actuator interfaces, with a multimeter during bring-up. That is not a stability run.

What failed earlier

The grip test took out the control board and half the actuators. That replacement is still open. It is a different fault from the servo that sat still.

Limitations

  • Fuse markings are not mapped to a branch. CURRENT_S and VOLTAGE_S are on the power schematic and have not been logged.
  • No photo of a replacement control board after the grip test.
  • A power cycle was not tested, so turn-on and turn-off behavior is unknown.
  • Extended actuator endurance, current-consumption logging, and voltage stability over a long run have not been done.
Bench notes

The longer design notes, the timeline, and the revisions. The sections above are the system and what I measured.

Context

What this is for

The boards and the servo path are above. This note is only the open fault: a grip test broke a printed link, and that story is written once under When it broke. Meter checks on the boards in hand are 12 V and 6 V. The fuse markings are still not a map.

Requirements

  • Switch actuator current in the 5–20 A range without taking the control board with it.
  • Keep a fused path on the power board and a regulated rail. The fuse markings are still not mapped to a branch.
  • Talk to the actuators over RS-485 and I2C.
  • Be able to check 12 V and 6 V with a meter before blaming firmware.

My part

What I took on

I modified the power and logic boards, checked the rails with a meter, and brought up the Teensy servo path on the logic board. The grip-test cascade is still the earlier failure on record. I don't have a photo of a replacement control board.

Work I did

  • Fused paths, DC-DC regulation, and RS-485 and I2C, as one set of changes on the two boards.
  • Meter checks of the 12 V and 6 V rails and the actuator interfaces.
  • Diagnostic firmware on the Teensy: bus scan, register readback, 50 Hz PWM, and the GPIO 6 enable that let the servo move.

Already there

  • The SR-01 logic and power boards, including V1 on the homework sheet and the later V2 pair I tested. I did not draw a new schematic for this page, and I did not design the chassis.
  • The climbing robot the boards belong to. I modified these two boards. I did not design the chassis.

Engineering Breakdown

Broken down by discipline

Each block is the requirement, how that part works, what I checked, and what is still open.

01Power

Power

Goal

Feed actuators that can draw 5–20 A without letting a fault take the control board.

Design

Fused circuits in that current range, and DC-DC regulation, on the power and logic boards I modified. The power board in hand has the yellow XT60, green terminal blocks, and blade fuses marked 15 and 5. A closer photo shows ATAZ UMD40 modules marked for 12 V and 5 V outputs. I looked at those modules for distribution and for adding a rail later, and at keeping the power routing off the signal routing, plus reverse-current protection. I check 12 V and 6 V with a multimeter before I trust an actuator channel. Those meter checks are not a fuse map, and they are not an EMI or protection test.

Challenges

  • The grip-test cascade, including the failed control board, is written under When it broke.
  • The brushed-to-BLDC saw change is unfinished. The reason for trying it, and what is still missing, is in that same fault note.

Iterations

  • Rail and connector checks with a multimeter when a channel doesn't come up.

Final implementation

The fused power board and the logic board are in hand. The control board from the grip test has not been replaced in a bring-up note.

Power board
Power board held on a clear plate, with a yellow XT60 and blade fuses

An earlier power board: yellow XT60, green terminal blocks, and blade fuses marked 15 and 5. This is not the V2 board I tested, and I haven't mapped those fuses to rails.

DC-DC modules
Power board with two black ATAZ DC-DC modules and green terminal blocks

V2 power board. ATAZ UMD40 modules marked for 12 V and 5 V outputs. The labels are what the parts say. This photo is not a load test.

Key Design Decisions

Design decisions

DecisionAlternativeWhy
Fuse the actuator pathLeave the actuator supply unprotected and hope the driver limits current.I put 5–20 A fused circuits, DC-DC regulation, and RS-485 and I2C onto the power and logic boards as one set of changes.
Notes on these decisions

Fuse the actuator path

A stalled or suddenly unloaded stepper can push current back into the control electronics. The grip test did that.

Fuses and a DC-DC stage add parts and a voltage drop. They also give a place for the fault current to stop. The fuse sheet is on the power board. I still have not mapped the 15, the 5, or the later 30 A markings to a branch.

I put 5–20 A fused circuits, DC-DC regulation, and RS-485 and I2C onto the power and logic boards as one set of changes.

Evolution

How it got here

The steps I can put in order from the notes. A clip opens from its still.

  1. Boards

    Power and logic in the SR-01 set

    V1 is the pair on the homework sheet. The boards went through more than one revision after that. Rail bring-up, 12 V and 6 V, was on V2.

  2. Failure

    The grip test

    The printed link broke while grabbing a branch. Stepper current fed back, signals were delayed by about 5 seconds, and the control board and half the actuators failed.

  3. Bring-up

    I2C to a servo

    Diagnosed and cleared an active-low output-enable fault on the PCA9685. Driving GPIO 6 low moved a servo through the V2 logic board at 50 Hz. Endurance, current logging, and a long voltage check are still open.

Reflection

Looking back

What surprised me, what I'd redo, and questions I'm still chewing on.

What surprised me

  • The plastic link was part of the electrical path. When it broke, the current spike killed the control board.

What I would redesign

  • Finish the brushed-to-BLDC saw change only after there is a current measurement, not just the reason for trying it.

Future improvements

  • Replace the failed control board and bring the rails back up on the new board.
  • Map the fuse markings to the branches on the power sheet.
  • Run the servo long enough to log current and watch the rail. That test has not started.

Questions that emerged

  • Which of the 5–20 A fuses is the one marked 15 on the power board, and what are the others?

Notes

  • OE is active low. A controller that accepts a register write can still hold every output off.
  • Check 12 V and 6 V before rewriting a driver that might just be unpowered.
  • The numbers written under the boards in one photo are homework, not rail measurements.

Same work