One layer at a time. A sender log at a steady rate only proves the sender is running, so the next check was whether the destination address was still Pi 2. With the network set aside, I metered the motor pack and found it drained. After that pack was replaced, the board read 12 V. The servos still reported 4.8 to 5.0 V, so I checked each motor connection for a drop between the board and the joint. A scan with Wi-Fi off failed the same way, which put the fault on the servo side rather than the hotspot. I don't have a per-joint drop written down, and I have not metered the voltage at a servo plug.
Missing power, a disconnected path, and a software hold all park the arm. A process that already owns the follower's serial port will ignore new commands. A USB-C address that was not set again after an unplug will too. A sender that is logging on time can still be sending angles that never arrive. I treated those as open until a measurement closed one of them.
Meter the reported 5 V. Power-cycle the pair and see whether that clears a held port, a stale address, or neither. Mount the follower up on SR-01 and run the same bridge there. A motor supply the Pi does not share is a build change, not a test I have run.