Lab 4
Op-Amp Comparators and an Intensity Display System
Power an LM324AN and use one amplifier as a comparator, then use that comparator in an intensity display.
Objective
Bring the LM324AN up from +5 V and -5 V, confirm the comparator switches, and use it in an intensity display.
Takeaway
The inverting input stayed near 2.5 V. The output sat near -4.997 V, then switched to about 3.758 V. With ±5 V rails the LM324AN reaches the negative rail and stops short of the positive one.
Setup
LM324AN, 4.7 kΩ resistors checked with an ohmmeter, and a voltmeter referenced to circuit ground.